AAPM

14 papers · 33 extracted observations · ct reconstruction · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Ct Reconstruction, split=test.

26.332.839.245.7202120222023EPNet (ExtraPolationNetwork): 27.63 (2021)SCOPE: 42.18 (2023)SCOPE: 44.33 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 10 of 10 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024Blaze3DM proposedPSNR ↑38.39Sparse View Ct Reconstruction · split: test · compressed · views=36Blaze3DM: Marry Triplane Representation with Diffusion for 3D Medical Inverse Problem Solving
Source quote
L221: Blaze3DM (Ours) │ 38.39 │ 0.951 │ 0.951 │ 0.951 │ 38.13
2022Proposed patch-wise deep metric learning proposedPSNR38.110Image Denoising · split: testPatch-Wise Deep Metric Learning for Unsupervised Low-Dose CT Denoising
Source quote
L132: PSNR │ 33.300 │ 38.110 │ 37.855 │ 37.795 │ 37.736 │ 37.673
2022SCOPE proposedPSNR42.18Ct Reconstruction · split: test · beam=parallel · views=90Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L214: 90 │ 24.40/0.4328/0.3424 │ 22.37/0.6937/0.0747 │ 38.89/{\color{blue}{0.9664}}/0.0139 │ {\color{blue}{41.95}}/0.9557/{\color{blue}{0.0078}} │ 41.74/0.9587/0.0079 │ {\color{red}{42.18}}/{\color{red}{0.9794}}/{\color{red}{0.0066}}
2022SCOPE proposedPSNR44.33Ct Reconstruction · split: test · beam=parallel · views=120Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L215: 120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}}
2022Invertible-cycleGAN baselinePSNR37.855Image Denoising · split: testPatch-Wise Deep Metric Learning for Unsupervised Low-Dose CT Denoising
Source quote
L132: PSNR │ 33.300 │ 38.110 │ 37.855 │ 37.795 │ 37.736 │ 37.673
2022FBPConvNet baselinePSNR41.95Ct Reconstruction · split: test · beam=parallel · views=90Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L214: 90 │ 24.40/0.4328/0.3424 │ 22.37/0.6937/0.0747 │ 38.89/{\color{blue}{0.9664}}/0.0139 │ {\color{blue}{41.95}}/0.9557/{\color{blue}{0.0078}} │ 41.74/0.9587/0.0079 │ {\color{red}{42.18}}/{\color{red}{0.9794}}/{\color{red}{0.0066}}
2022FBPConvNet baselinePSNR44.14Ct Reconstruction · split: test · beam=parallel · views=120Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L215: 120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}}
2021Cycle-free CycleGAN with invertible generator (Proposed) proposed non-standard slicePSNR34.940Ct Denoising · split: test · dose=25% of standard dose · subset=421 test imagesCycle-Free CycleGAN Using Invertible Generator for Unsupervised Low-Dose CT Denoising
Source quote
L568: Proposed │ 34.940 │ 0.821
2021EPNet (ExtraPolationNetwork) proposedPSNR27.63Ct Reconstruction · split: test · noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram Extrapolation
Source quote
L160: EPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859
2021AdaIN-based CycleGAN baseline non-standard slicePSNR34.801Ct Denoising · split: test · dose=25% of standard dose · subset=421 test imagesCycle-Free CycleGAN Using Invertible Generator for Unsupervised Low-Dose CT Denoising
Source quote
L567: AdaIN-based CycleGAN │ 34.801 │ 0.824