AAPM
14 papers · 33 extracted observations · ct reconstruction · Markdown · CSV · JSON API
Tasks on AAPMAll tasks (14)Ct Reconstruction (4)Image Denoising (3)Image Reconstruction (3)Artifact Removal (1)Ct Denoising (1)Dose Prediction (1)Sparse View Ct Reconstruction (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Ct Reconstruction, split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | SCOPE SOTA frontier (+1 variant) | 44.33 | 2023-01-01 | beam=parallel · views=120 · 120 input views; AAPM test set (4 slices). SCOPE reconstructs from a single SV sinogr… | Self-Supervised Coordinate Projection Network for Sparse-View Computed TomographySource quote120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}} |
| 2 | EPNet (ExtraPolationNetwork) SOTA frontier | 27.63 | 2021-01-01 | noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 · αmax=60. NIH-AAPM test split: 1,716 slices from five patients; models trained on 1,74… | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteEPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |
Other primary task on AAPM: Ct Reconstruction · SSIM ↑ · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DEFT SOTA frontier | 0.887 | 2024-01-01 | angles=60 · sampling-steps=100 DDIM · measurement-noise=Gaussian, σ_y=1.0 · Parallel-beam Radon transform with 60 angles and Gaussian measurement noise σ_y = 1.0… | DEFT: Efficient Fine-tuning of Diffusion Models by Learning the Generalised $h$-transformSource quoteSSIM │ 0.885 │ 0.865 │ 0.887 │ 0.846 │ 0.849 │ 0.876 |
| 2 | EPNet (ExtraPolationNetwork) SOTA frontier | 0.882 | 2021-01-01 | noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 · αmax=60. NIH-AAPM test split: 1,716 slices from five patients; models trained on 1,74… | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteEPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |
TaskCt Reconstruction (15)Image Denoising (7)Image Reconstruction (6)Ct Denoising (2)Sparse View Ct Reconstruction (1)Artifact Removal (1)Dose Prediction (1)
Splittest (13)
Showing 1 of 1 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | ADDiff-Dose proposed | DICE | 0.927 | Dose Prediction | Conditional Diffusion Model with Anatomical-Dose Dual Constraints for End-to-End Multi-Tumor Dose PredictionSource quoteL475: To verify the performance advantages of the proposed model in dose prediction tasks, we conducted a comprehensive comparison with current mainstream advanced models, including UNet~\cite{bertels2022convolutional}, GAN~\cite{goodfellow2014generative}, DeepLabV3+ \cite{chen2018encoder}, MD-Dose ~\cite{fu2025mddosediffusionmodelbased}, DoseDiff ~\cite{10486983} and DoseNet ~\cite{kearney2018dosenet}. The experimental results, as shown in Tables 3 and 4, demonstrate that the proposed model exhibits significant advantages across multiple core metrics. In terms of the MAE metric, the error values of the proposed model on the public dataset, the Affiliated Hospital of Xiangnan University, Chenzhou Third People's Hospital, and Jiangxi Provincial Cancer Hospital are 0.101, 0.103, 0.139, and 0.154, respectively, all lower than those of other compared models (e.g., DoseNet has an MAE of 0.156 on the public dataset). Notably, on the two key metrics of \DeltaHI (0.038 ± 0.004) and \Delta D_{\text{98}} (0.024 ± 0.011), compared to DoseNet, which ranked second (\DeltaHI = 0.042 ± 0.018, \Delta D_{\text{98}} = 0.032 ± 0.017), the proposed model reduced the values by 0.004 and 0.008, respectively, showing a significant improvement in error control capability. Additionally, on the \Delta D_{\text{2}} (0.001 ± 0.001) and \Delta D_{\text{max}} (0.0005 ± 0.0006) metrics, the values of the proposed model are only 1/10 to 1/3 of those of other advanced models, highlighting its superior spatial localization accuracy. Through paired t-test analysis, the differences between the proposed model and models such as UNet, GAN, DeepLabV3+, and DoseNet in terms of metrics like MAE, DICE, and HD95 are statistically significant (P < 0.05), proving that the performance improvements are not coincidental. To further benchmark our model against contemporary diffusion-based approaches, we compared ADDiff-Dose with the reported performance of DoseDiff ~\cite{10486983} and MD-Dose ~\cite{fu2025mddosediffusionmodelbased} on the AAPM dataset. As shown in Table 2, ADDiff-Dose achieves a superior MAE of 0.101 and DICE of 0.927, compared to DoseDiff (MAE: 0.118) and MD-Dose (DICE: 0.905), underscoring the benefit of our dual-constraint design and lightweight VAE. |