Hang Shao
· 4 previous affiliations
- Qingdao UniversitySince 2025
- Senior Lecturer · Since 2025
- PhD student · 2021–2025
- Research Assistant · 2022–2023
- MS student · 2018–2021
2 other authors named Hang Shao: Hang Shao (Tencent (China) · Shanghai Jiao Tong University · 15 papers), Hang Shao (University of Utah · 1 paper)
Research Overview
Hang Shao focuses on computer vision and remote physiological sensing, specifically developing video-based methods for estimating vital signs like heart rate and blood pressure. Early work explored spatiotemporal graph convolutional networks for remote photoplethysmography, while recent efforts emphasize transformer-based architectures to disentangle physiological signals from environmental noise. Current research addresses robust, non-contact health monitoring applications across diverse clinical metrics.
Research Trajectory
The available evidence from 2023 and 2024 outlines a focused research trajectory in remote photoplethysmography (rPPG) and non-contact physiological measurement. The core technical challenge addressed throughout this work is the extraction of subtle, invisible biological signals from facial videos while mitigating the effects of environmental noise, subject movement, and varying lighting conditions.
In 2023, Shao's research emphasized modeling the complex spatial and temporal dynamics of facial videos. This early approach is exemplified by Hyperbolic embedding steered spatiotemporal graph convolutional network for video-based remote heart rate estimation, where Shao served as first author. The research utilized graph convolutional networks to extract physiological signals from video data, establishing a foundation for subsequent methodological improvements in non-contact vital sign monitoring.
By 2024, Shao's methodological focus shifted toward transformer-based architectures to better handle long-term temporal dependencies and complex interference. As first author, Shao introduced novel paradigms for disentangling true physiological signals from noise. In TranPulse: Remote Photoplethysmography Estimation With Time-Varying Supervision to Disentangle Multiphysiologically Interference, the research addressed the limitations of existing deep networks in eliminating long-term time-varying interference, proposing a video transformer approach to isolate implicit biological characteristics. This was closely followed by TranPhys: Spatiotemporal Masked Transformer Steered Remote Photoplethysmography Estimation, which utilized a masked transformer network to improve spatiotemporal interactive perception. This architecture allowed the model to robustly overcome various visual disturbances that typically degrade rPPG performance.
During this same period, Shao also explored self-supervised learning techniques for physiological sensing, leading the development of PCA Lab's Solution for RePSS 2024 by Vision-based Self-supervised Remote Heart Rate Sensing. Beyond heart rate estimation, Shao participated as a middle author in collaborative efforts to expand the capabilities of remote health screening to new modalities. This included work on FeverNet: Enabling accurate and robust remote fever screening, which introduced depth estimation and temperature distribution constraints to prevent measurement errors caused by distance changes without relying on external sensors. Additionally, Shao contributed to Video-based Remote Blood Pressure Measurement Using Convolutional Networks and Random Forest, demonstrating an ongoing interest in applying computer vision to a broader array of clinical metrics.
Current Directions
The most recent papers in the evidence, all published in 2024, indicate a continued focus on improving the robustness and clinical utility of video-based physiological measurement. A primary theme in this recent work is the transition from supervised, feature-specific recognition to self-supervised and transformer-driven models capable of disentangling complex, implicit biometrics from environmental noise. Furthermore, the expansion from remote heart rate estimation to non-contact fever screening and blood pressure measurement suggests an ongoing effort to build comprehensive, multi-metric remote health monitoring systems that can operate reliably in unconstrained, real-world environments.
Profile updated
| Title | Venue | Year |
|---|---|---|
| External Illumination De-Interfering for Remote Photoplethysmography | Openreview | 2026 |
| FeverNet: Enabling accurate and robust remote fever screening | Pattern Recognition | 2024 |
| Video-based Remote Blood Pressure Measurement Using Convolutional Networks and Random Forest | RePSS @ IJCAI | 2024 |
| PCA Lab's Solution for RePSS 2024 by Vision-based Self-supervised Remote Heart Rate Sensing | RePSS @ IJCAI | 2024 |
| TranPhys: Spatiotemporal Masked Transformer Steered Remote Photoplethysmography Estimation | IEEE TCSVT | 2024 |
| TranPulse: Remote Photoplethysmography Estimation With Time-Varying Supervision to Disentangle Multiphysiologically Interference | IEEE Trans. Instrumentation & Measurement | 2024 |
| Hyperbolic embedding steered spatiotemporal graph convolutional network for video-based remote heart rate estimation | Engineering Applications of AI | 2023 |
Loading new papers…
Other researchers whose papers cluster into the same research directions — a proxy for overlapping technical interests and shared intellectual neighborhoods.
See something wrong? Report a mistake