Abouzar Eslami
· 4 previous affiliations
- Carl Zeiss (Germany)Since 2013
- Principal Researcher · Since 2013
- Technical University of Munich2011–2013
- Postdoc · 2011–2013
- Sharif University of Technology2002–2010
- PhD student · 2005–2010
- MS student · 2002–2005
- Amirkabir University of Technology1998–2002
- Undergrad student · 1998–2002
Research Overview
Abouzar Eslami focuses on medical image analysis, computer-assisted interventions, and representation learning for healthcare applications. His trajectory spans from early collaborative work in surgical tool tracking and robotic ophthalmic microsurgery to senior roles developing deep learning architectures for retinal disease segmentation. Most recently, his research addresses the interpretability, fairness, and privacy of machine learning models in clinical settings.
Research Trajectory
Eslami's early recorded work in the mid-2010s focused on the intersection of computer vision and medical imaging, particularly in overcoming the challenges of multi-modal image registration and surgical tool tracking. In Deformable Registration of Multi-modal Microscopic Images Using a Pyramidal Interactive Registration-Learning Methodology, he participated in developing an interactive method to co-register functional fluorescence and structural histology images. By synthesizing histology images from multi-channel fluorescence inputs via supervised machine learning, the research team reduced a complex multi-modality problem into a more tractable mono-modality registration task. During this period, he also contributed to tracking algorithms for retinal microsurgery, utilizing regression forests to estimate tool poses despite partial occlusions and illumination changes.
Moving into the late 2010s, Eslami's collaborative efforts increasingly targeted the integration of deep learning into computer-assisted interventions, with a specific emphasis on ophthalmic procedures. He contributed to research on real-time instrument tracking in Concurrent Segmentation and Localization for Tracking of Surgical Instruments. This work addressed specular reflection and motion blur by reformulating 2D pose estimation as a heatmap regression problem, allowing for the simultaneous and robust regression of both localization and segmentation tasks. Concurrently, Eslami was part of a broader research initiative exploring robot-assisted eye surgery. In Towards Robotic Eye Surgery: Marker-Free, Online Hand-Eye Calibration Using Optical Coherence Tomography Images, he collaborated on a flexible, marker-free framework to calibrate an ophthalmic robot with a microscope-integrated Optical Coherence Tomography (OCT) system, a critical step toward translating robotic dexterity into clinical practice.
By 2019, Eslami's profile demonstrates a shift toward more central roles in both applied medical image analysis and foundational representation learning. As senior author, he led research into diabetic retinopathy progression in Multi-scale Microaneurysms Segmentation Using Embedding Triplet Loss. This two-stage deep learning approach utilized multiple input scales and selective sampling, incorporating a triplet embedding loss to enhance the discriminative power of the classification model for microaneurysm segmentation. In parallel, he made significant contributions as a second author to the broader challenge of model explainability in Learning Interpretable Disentangled Representations Using Adversarial VAEs. This research introduced a novel adversarial variational autoencoder constrained by total correlation, enforcing independence on the latent representation to produce compact, interpretable features without sacrificing reconstruction fidelity.
In his most recent observed work, Eslami has participated in addressing the ethical and privacy constraints of deploying machine learning in healthcare. In On the Fairness of Privacy-Preserving Representations in Medical Applications, he collaborated on a framework designed to learn invariant, fair representations by decomposing data into target and sensitive codes. By imposing an entropy maximization constraint, the model ensures the target code remains invariant to sensitive nuisance factors, facilitating privacy-preserving federated learning applications.
Current Directions
The most recent papers in the evidence, dating to 2020, indicate a dual focus on the ethical deployment of medical machine learning and the continued refinement of surgical robotics. On the algorithmic front, recent work investigates how to build data-driven clinical models that are not only accurate but also interpretable, fair, and privacy-preserving. This involves exploring latent space disentanglement and adversarial training to remove sensitive patient information from learned representations. Concurrently, Eslami remains engaged in the hardware-software integration required for delicate ophthalmic procedures, with recent collaborative efforts addressing the design and OCT-guided navigation of hybrid parallel-serial robot systems for subretinal injections.
Profile updated
| Title | Venue | Year |
|---|---|---|
| Towards Robotic-Assisted Subretinal Injection: A Hybrid Parallel-Serial Robot System Design and Preliminary Evaluation | IEEE Trans. Industrial Electronics | 2020 |
| On the Fairness of Privacy-Preserving Representations in Medical Applications | DART/DCL @ MICCAI | 2020 |
| Fairness by Learning Orthogonal Disentangled Representations | ECCV | 2020 |
| Multi-scale Microaneurysms Segmentation Using Embedding Triplet Loss | MICCAI | 2019 |
| Learning Interpretable Disentangled Representations Using Adversarial VAEs | DART/MIL3ID @ MICCAI | 2019 |
| Needle Localization for Robot-assisted Subretinal Injection based on Deep Learning | ICRA | 2019 |
| 6DOF Needle Pose Estimation for Robot-Assisted Vitreoretinal Surgery | IEEE Access | 2019 |
| Fast 5DOF needle tracking in iOCT | Int. J. Comput. Assist. Radiol. Surg | 2018 |
| Towards Robotic Eye Surgery: Marker-free, Online Hand-eye Calibration using Optical Coherence Tomography Images | IEEE RA-L | 2018 |
| Precision Needle Tip Localization Using Optical Coherence Tomography Images for Subretinal Injection | ICRA | 2018 |
Loading new papers…
Other researchers whose papers cluster into the same research directions — a proxy for overlapping technical interests and shared intellectual neighborhoods.
See something wrong? Report a mistake